Maintenance of UV visible spectrophotometer

Writer:公司Source:公司 Number of visits: Date:2016-8-18
                                Maintenance of UV visible spectrophotometer
UV VIS Spectrophotometer in daily use will produce some wear and dirt, for the use of the performance of the instrument will have a certain impact, so for the daily maintenance of UV VIS spectrophotometer is indispensable. Today we will introduce the main points of the maintenance of UV visible spectrophotometer.
UV VIS spectrophotometer using a new technology, its powerful function, using the monochromator technology, the wavelength range of 190-1100nm, is a common instrument relates to the field of industrial detection analysis, such as steel, water and wastewater, drinking water applications include the foundry, steel plant, machinery plant, quality inspection, measurement of municipal and industrial wastewater,, process water, surface water, cooling water and boiler water supply etc..
Maintenance of UV visible spectrophotometer:
Temperature and humidity are the important factors that affect the performance of the instrument. They can cause corrosion of mechanical parts, metal mirror finish down, cause a decrease of the mechanical parts of the instrument error or performance; aluminum corrosion caused by optical components such as gratings, mirrors, focusing mirror etc., to produce energy shortage, stray light and noise, and even the instrument to stop working, thereby affecting the life of the instrument. Maintenance should be periodically corrected. Should have four humidity of the instrument room, configuration of the thermostatic device, is located in the south area of the laboratory.
Dust and corrosive gas environment in two, will also affect the flexibility of the mechanical system and reduce the reliability of various limit switches, buttons, photoelectric coupler, is caused by one of the reasons must learn parts of aluminum film corrosion. Therefore must be cleaned regularly, to protect the environment and equipment indoor hygiene conditions, dust, etc..
For a period of three, the instrument after use, will accumulate a certain amount of dust, preferably by the engineer or under the guidance of the engineer regularly open the equipment cover dust work on the inside, while the radiator heating element fastening, sealing window on the optical box in clean, to calibrate the optical path when necessary, for lubrication, cleaning and necessary for the mechanical part of the final, restitution, then some of the necessary testing, calibration and recording
                                                                           Nanjing Ning Bo Analytical Instrument Co., Ltd.
                                                                                                     2016-8-31

TypeInfo: Industrial News

Keywords for the information:Ultraviolet visible spectrophotometer.