A、instrument
NB - 800 direct reading spectrometer is widely used in metallurgy, casting, machinery, metal processing, automobile manufacturing, nonferrous metal, aerospace, weapons, chemical and other areas of the production process control, finished product testing center laboratory, is one of the effective means to control the quality of the products. Mainly used for various metal and its alloy material of chemical elements in accurate component analysis, qualitative and quantitative detection, convenient and quick. NB - 800 direct reading spectrometer draw lessons from the advanced features of several instruments both at home and abroad, through the industry experts and scholars meticulously, prominent instrument use accurate and stable, fast and convenient features, with its excellent performance, a new design, advanced technology in domestic and foreign markets; Equipment daily maintenance simple, low running cost, low failure rate.
B、the main characteristics
Low optical system with 750 mm focal length, palmer XingLong lattice structure, the dispersion effect is good, grating using grating Newport, companies in the United States and France JY company optimal products;
Chemical elements are of low metal industry needs analysis, including: trace carbon (C), phosphorus (P), sulfur (S). Applicable to the analysis of the corresponding matrix (base metal), such as Fe, Al, Cu, Ni, Co, Ti, Mg, zinc, Pb, Sn. Covers the whole scope of element analysis, can choose according to specific needs analysis element;
Low photomultiplier tube high pressure can be controlled by computer to each channel to provide several high pressure, the same channel can be applied in the different analysis program, greatly improve the utilization rate of the channel;
Independent exit slit structure, they sewed and optional wide, the position can be adjusted accurately, to improve the accuracy and precision of the element analysis;
Low spectral system adopts dynamic installation, can reduce the influence of temperature, material stress changes;
Low excitation light directly into the vacuum chamber;
With automatic constant temperature system, guarantee the light room temperature 35 ℃ + / - 0.2 ℃, can reduce the environmental temperature fluctuations on the instrument and the effect on the stability of the optical system;
The core of low spectrometer components all adopt the world famous professional manufacturers of products. The photoelectric conversion element using in Japan's hamamatsu photomultiplier tube; Other parts also bought more world famous manufacturers, instrument reliability were fully guarantee;
When using Japan's imports of photomultiplier tube: high signal-to-noise ratio, low dark current, long life;
Low light chamber vacuum automatic control technology, for the world advanced technology in the field of the spectrometer. Light vacuum application special MCU program of automatic control technology for automatic control, greatly improving the long-term stability of the instrument;
Low automatic high pressure system for the world's advanced level. The system can through the computer control for each channel 8 high pressure, so the same channel can be applied in the different analysis program, greatly improving the channel utilization and spectral lines of best linear range used in the analysis of different materials, reduced the number of channel of the, reduces the cost;
Low fully automatic computer control stepping motor automatic tracing for the world's advanced level, fully automatic tracing can greatly shorten the time required for calibration instruments, make calibration is simple, convenient, non-professional personnel as well as for tracing operation;
Each system is independent power supply, unitized design, the maintenance convenient and quick. Unitized design can achieve rapid maintenance of paraprofessionals, for Internet remote diagnosis instrument fault well prepared;
Analysis of low speed quick, the chemical composition of 20 seconds to closed all the channels. According to different analysis material, by analyzing the precombustion curve to determine the time, make the instrument with the analysis of the shortest possible time to achieve the optimal effect;
Chinese operating software under low xpista WINDOWS system, domestic users' convenience. Different levels of operator can call at any time in the help menu to guide to the operation of the instrument. And there are many languages system, can make it easy to use for foreign users.
C、the main performance
(1) excitation light source
1、 the power supply voltage: 50 hz, 220 v + / - 1%
2、 the input power: 1.0 KVA
3、 peak current, precombustion 100 a, exposure to 20 a
4、 the peak pressure of main loop: 300 VDC (using automatic adjusting peak pressure)
5、 ignition circuit, pulse amplitude: + 15 kv
6、 assist clearance: the tunnel diode
7、 discharge frequency: 200 Hz ~ 600 Hz
8、 and sample analysis clearance: 4 mm
(2) spectrometer
1、analytical wavelength range: 130 ~ 800 nm
2、 machine carved concave grating: curvature radius of 750 mm
3、 the density of score: 2400 / mm
4、 incidence Angle: 35 degrees
5、 allowed passage: to expand to 64 channels
6、 spectrometer local constant temperature 35 ℃ plus or minus 0.2 ℃
(3) the measurement and control system
1、 adopt single machine measurement and control, data exchange with computer to
2、 reproducibility: RSD 0.2% or less
3、 photomultiplier tube high voltage power supply
4、 stability: eight hours is better than 0.5%
5、 high pressure regulating: changes from 550 v to 1000 v, and 8 (0 to 7) adjustment
6、 high pressure Settings: the user through the computer software change
(4)、 the technical parameters:
1、the optical system:
U Mr Xing - runge optical system
Taken the focal length of 750 mm.
Taken the holographic concave grating groove 2400 / mm
Taken the spectral range 130-800 nm
U up to 64 channel analysis
Taken the dispersion rate: primary spectrum: 0.55 nm/mm,
Taken the secondary spectrum: 0.275 nm/mm
Taken the resolution: better than 0.01 nm
2、 the vacuum system:
Taken the excitation light path directly into the vacuum chamber
Taken the minimum leakage, reduce the vacuum pump running time
Taken the rotary vane vacuum pump
Taken the vacuum automatic control, less than 3 pa
Taken the vacuum isolation valve
3、 thermostatic system:
Taken the optical chamber adopts constant temperature system
Taken the temperature automatic control: 35 ℃ plus or minus 0.2 ℃
Taken to avoid the influence of temperature fluctuation on the stability of instrument
4、sparks machine:
Taken the spark machine size: 100 x90 mm
U have a safety protection device
Taken the optimization of low argon gas consumption
U easy disassembly, easy to clean
Taken the pneumatic sample to adapt to the various sample shape
Taken the electrode life is more than one hundred thousand times
5、 spark excitation light source:
Taken the pulse discharge light source
U all solid-state circuits, without auxiliary clearance
U all parameters by the computer control of the spectrometer
Taken the excitation light source frequency 200 hz - 600 hz
U have to prevent short circuit function
6、 measuring control system:
U hv automatic adjustment, is controlled by computer software
Taken the high voltage stability is better than 0.2%
U have a self-check function circuit
Taken the modular design, convenient and increase the channels
7、 spectrometer software:
Taken the Windows XP or Windows Vista operating system
Taken the analysis data directly to the weight percentage output
U completely standardized
Taken the analysis element of background correction, the correction of the 100% and the matrix
U support equivalent C and other setting parameters are calculated and output
Taken the data storage function
U complete sample management system
Taken the multinational language systems, such as English, Russian, Korean, Japanese, etc. Optional.
8、argon gas supply:
Taken the purity: more than 99.995%
Taken the pressure: 0.3 MPa
9、the power consumption:
Taken the 1.5 KW
Taken the analysis of a sample time about 20 seconds
The size and weight of 10, instrument:
High end 1020 long and 1020 wide (1020 mm)